AC Transit Richmond Hydrogen Electrolysis Station
|
|
|
|
|
|
Status
|
out of operation
|
|
Start date - end date
|
30.10.2002 - 15.01.2008
|
|
Last changes
|
22.01.2008 The station was dismantled.
|
|
Public access
|
|
|
Location
|
|
United States
California
|
|
94801
Richmond
|
|
AC Transit Richmond Division,
|
|
2016 MacDonald Ave Richmond
|
probably exact location
Show Station on map
|
|
Goal
|
Primarily used for fueling AC Transit's 30' prototype fuel cell buses and light-duty vehicles traveling from the CaFCP headquarters in West Sacramento.
|
|
Description
|
The station can fuel as many as five cars within approximately eight minutes, at pressures of 5,000 psi (35 MPa) and 3,600 psi (25 MPa).
|
|
Operator
|
|
|
Technology provider
|
|
|
Further partners
|
AC Transit (Alameda-Contra Costa Transit District)
|
|
Fuel
|
|
|
Hydrogen supply
|
electrolysis - on-site 24kg/day
|
|
Hydrogen storage
|
CGH2 (47kg)
|
|
Vehicles served
|
CaFCP 30' prototype fuel cell buses and light-duty vehicles
|
|
Station-contact
|
|
|
Station-site
|
www.actransit.org
|
|
Comments
|
|
|
LBST-Info
|
This Information is provided by LBST. LBST Station ID: 057 Please notice the Terms of Use. If you need more information or maps, please click here.
|